Concrete Contractors of Irving Logo
Structural Columns & Cores commercial concrete contractors

Service profile

Structural Columns & Cores

High-rise cores, columns, and shear walls coordinated with PT slabs and steel framing for hybrid structures.

Mobilization
5-7 days
QA reporting
Daily field logs
Packages delivered
400+
Crew coverage
Irving & Metroplex
Self-performed
Core scope crews
Average variance
<1% schedule

About Structural Columns & Cores

Structural columns and elevator/stair cores form the vertical load-carrying elements of multi-story commercial buildings. These critical components must meet exact dimensional tolerances, carry massive loads, and integrate with floor slabs and foundations to create stable structural systems.

As your general contractor for vertical concrete elements, we construct columns and cores for office buildings, parking structures, hotels, and mixed-use towers throughout the DFW Metroplex. Our work includes formwork coordination, reinforcement placement, concrete pumping to elevation, and the quality control required for structural elements.

High-rise construction demands precision—columns must plumb vertically floor-to-floor, embed plates must align for steel connections, and concrete strength must meet design requirements for early stripping and reshore cycles. We provide the survey control, QA/QC systems, and experienced crews necessary for vertical construction quality.

Elevator cores present additional complexity with embedded door frames, mechanical sleeves, and the tight dimensional control required for elevator guide rail installation. Our core construction experience includes coordination with elevator installers to ensure every embed and dimension supports successful elevator commissioning.

What's Included

  • Column forming and shoring systems
  • Core forming (elevator and stair)
  • Reinforcement and post-tensioning anchorages
  • Embedded items and sleeves
  • Concrete pumping and placement
  • Survey control and plumb verification
  • Early strength testing for stripping
  • Documentation for structural engineer

What this scope delivers

As your general contractor, we engineer, schedule, and execute structural columns & cores packages across Irving, TXfor commercial and industrial projects. Property owners and developers get direct accountability, transparent pricing, and professional project management.

Design-assist alignment

We plug into preconstruction early, reviewing drawings for embed coordination, lift plans, and pour sequencing so structural columns & cores aligns with the broader build.

Crewed for Metroplex speed

Dedicated concrete columns crews staged across the Metroplex shorten mobilization windows and keep manpower consistent through multi-phase scopes.

Transparent field reporting

Daily shear wall updates, photo logs, and testing summaries document every milestone for owner reps and construction managers.

QA/QC baked into pours

Laser layout, third-party testing, and post-pour walks confirm building cores requirements before downstream trades mobilize.

Commercial & Industrial Applications

Typical applications

Request a bid →
Office building columns and coresHotel and residential tower structuresParking structure columnsMixed-use vertical elementsHealthcare facility structural systemsInstitutional building cores

Execution framework

How we keep the scope on schedule

  1. 01

    Scope coordination

    We align drawings, RFIs, and finish standards with your team to confirm sequencing, logistics, and tolerances before structural columns & cores mobilizes.

  2. 02

    Site logistics & safety

    Detailed logistics maps, crane placement, and safety planning keep crews productive and compliant throughout structural columns & cores execution in Irving.

  3. 03

    Field execution

    Self-performed crews manage layout, formwork, placement, and finishing with superintendent oversight and real-time reporting.

  4. 04

    Close-out & turnover

    Punch walks, testing reports, and as-built documentation verify performance before handing off to downstream trades.

Quality and safety controls

  • Certified crews & audits

    Weekly safety stand-downs, JHAs, and third-party inspections keep our structural columns & cores teams compliant on every Irving, TX jobsite.

  • Testing & documentation

    We coordinate break tests, flatness readings, and special inspections with labs to maintain traceable records for owners and concrete columnss.

  • Communication rhythm

    Look-ahead schedules, coordination huddles, and daily reports ensure no surprises for the GC or owner reps.

Need project-specific QA/QC documentation, submittals, or safety plans? We assemble packages tailored to your owner and AHJ requirements before mobilization.

Measured outcomes

Results owners notice

Every structural columns & cores package is tracked against schedule, QA benchmarks, and owner punch lists so you can move to the next trade with confidence.

Schedule reliability
99% milestones met

Tracked through weekly look-aheads and daily updates to keep structural columns & cores scopes synced with other trades in Irving.

Owner punch items
<2 per project

Proactive walk-throughs and photo documentation keep finish quality tight and cut rework.

Testing compliance
100% logs filed

Cylinder breaks, floor flatness, and inspection reports uploaded within 24 hours of each pour.

Crew retention
5+ year leads

Experienced foremen guide every structural columns & cores phase, protecting craftsmanship and safety culture.

Frequently asked questions

Structural Columns & Cores in Irving, TX

Common questions from developers and property owners planning structural columns & cores projects across North Texas.

How do you maintain plumb on multi-story columns?

We use optical survey equipment to establish vertical control, transfer column lines floor-to-floor, and verify plumb as construction rises. Column forms include adjustment capability to correct any deviation before concrete placement.

What about high-strength concrete for columns?

High-rise columns often require concrete strengths of 6,000-8,000+ PSI to carry design loads in smaller column sizes. We coordinate appropriate mix designs, placement techniques, and curing methods to achieve specified strengths.

How do you coordinate elevator core embeds?

Elevator cores require dozens of embedded items—door frames, guide rail brackets, safety equipment anchors. We work from shop drawings, establish quality control checkpoints, and verify all embeds before concrete placement.

What about accelerated construction schedules?

Multi-story construction often uses jump forms or climbing systems to maintain rapid floor-to-floor cycles. We provide the forming systems and experienced crews necessary to support aggressive vertical construction schedules.

Ready when you are

Get a direct bid for your structural columns & cores project

Developers and property owners: share your plans and we'll provide a complete project proposal with transparent pricing and single-source accountability as your general contractor.

Let’s pour

Ready to start your next commercial concrete project?

Call NowStructural Columns & Cores | Concrete Contractors of Irving | Concrete Contractors of Irving